Dark Matter Detectors
The nature of dark matter remains one of the biggest open questions in physics, and many fundamental properties of neutrinos are still unknown. Liquid xenon detectors are among the most powerful tools to address both. Our group tackles the technological challenges of liquid xenon time projection chambers (TPCs) in preparation for the XENON-LZ-DARWIN (XLZD) Observatory, the planned next-generation, multi-ton detector that will search for dark matter and other rare processes such as neutrinoless double beta decay.
Our work spans the full development cycle of liquid xenon detectors: designing, building and testing high-voltage feedthroughs, developing calibration techniques, running Monte Carlo simulations, and performing statistical analyses to assess the sensitivity of future experiments like XLZD.
At the heart of our laboratory is MOTION, a TPC filled with 70 kg of liquid xenon. MOTION serves as a test platform for delivering high voltages of around −200 kV and for studying high-voltage stability in liquid xenon. A key goal is to understand the breakdown behavior of liquid xenon and how it depends on factors such as the electrode surface area and xenon purity. MOTION also lets us investigate spurious electron emission from electrodes and develop high-voltage feedthroughs made exclusively from radiopure materials.
For information on master and bachelor theses contact yanina.biondi∂kit.edu